acamenglishTransducers Direct Main Websitesolutions in time
homecontactsitemapdatasheetsNews
Transducers Direct Main WebsiteproductsTDCsTDC-GP1TDC-GP2TDC-F1TDC-GPXATMDcustomMethodApplicationsPICOSTRAINPS02PSA2MethodAdvantagesPerformanceApplicationsPICOTURNPICOTURN-BMMethodLegal

TDC-F1

OBSOLESCENCE NOTIFICATION

Last order date FEB. 28, 2008

8 channels with 120ps resolution

Features:

  • 8 channels with typ. 120 ps resolution
  • Optional 4 channels with typ. 60 ps resolution
  • Optional 32 hit-channels with typ. 5.7 ns resolution
  • accurately adjustable resolution via "Resolution Adjust Mode"
  • Measurement range: typ. 7.8 µs in normal resolution and 3.9 µs in high resolution
  • Multihit capability: normal resolution min. 4-fold up to unlimited, high resolution min. 8-fold
  • Programmable edge sensitivity: rising and/or falling edge
  • Disable inputs for all channels
  • Common Start mode (Time Stamp mode for common input)
  • Complex Trigger Matching unit for special demands in high energy physics
  • Differential low voltage pseudo-ECL inputs (LVPECL) for measuring channels, hit-channels and common input.
  • Reference clock range between 1 Mhz and 40 MHz
  • 24-Bit/8-Bit parallel read interface, serial write interface
  • PQFP160 package
  • separate I/O and core Power Supply

>>> Show block diagram


Download datasheet as PDF:
Indutrial version
/
(~700 kB)
Scientific version

(~ 1 MB)