Task:

Sensor:Fullbridge, 1000 Ohm SG
Sensitivity:2 mV/V
Update rate:5 Hz
Resolution:20,000 scale divisions
(6.6 sigma/div => 45nV rms noise)
Current consumptionoptimized for battery life time
Supply voltage:3 x AA, 3.0 V SG and core
Application:Industrial bench scale
Settings:

Measurement range 2, One-sense mode, Cycle time 270µs, AVRate 60, Temperature measurement, Gain and Rdson compensation.

Current consumption:

Current into strain gage and PS02 I/O section:
760 µA
Current into PS02 core:
140 µA
Oscillator:
150 µA
Comparator:
120 µA
Totel current:
1,170 µA