- Digital Amplifier for Strain Gages Temperature
Measurement The
K-factor of strain gages depends on temperature and decreases with higher temperature.
If the temperature of the strain gage is known, it is easy to correct for the
main failure (active temperature compensation). PSØ2
offers the option of temperature measurement with an external temperature sensitive
resistor. Basically
the temperature measurement is nothing more than a simplified SG measurement at
separate ports. A measurement takes 2 discharge/recharge cycles and is done once
per measurement sequence. In
the first cycle the capacitor is discharged through the temperature sensitive
resistor. The nominal value of the resistance should be minimum 500 Ohm. In the
second cycle the capacitor is discharged through a temperature stable reference
resistor. |